Discover 226 products
Image Part Number Manufacturer Quantity Delivery period Unit Price Buy Description Series Voltage - Supply Mounting Type Termination Style Delay Time Circuit Contact Rating @ Voltage Relay Type Timing Adjustment Method Timing Initiate Method
H3FA-A-DC24
Omron Automation and Safety
90
3 days
-
MOQ: 1  MPQ: 1
RELAY TIME DELAY 10MIN 3A 250V
H3FA 24VDC Through Hole PC Pin 0.1 Sec ~ 10 Min DPST-NO/NC (1 Form A and B) 3A @ 250VAC Mechanical Relay Screwdriver Slot Input Voltage,Trigger Signal
H3DT-A2 AC/DC24-240
Omron Automation and Safety
54
3 days
-
MOQ: 1  MPQ: 1
RELAY TIME DELAY 1200HR DIN RAIL
H3DT 24 ~ 240VAC/DC DIN Rail Spring Terminal 0.1 Sec ~ 1200 Hrs DPDT (2 Form C) - Solid State Relay Screwdriver Slot Input Voltage
H3DT-A1 AC/DC24-240
Omron Automation and Safety
9
3 days
-
MOQ: 1  MPQ: 1
RELAY TIME DELAY 1200HR DIN RAIL
H3DT 24 ~ 240VAC/DC DIN Rail Spring Terminal 0.1 Sec ~ 1200 Hrs SPDT (1 Form C) - Solid State Relay Screwdriver Slot Input Voltage
H3DS-AL AC24-230/DC24-48
Omron Automation and Safety
13
3 days
-
MOQ: 1  MPQ: 1
RELAY TIME DELAY 120HR 5A 250V
H3DS-A 24 ~ 230VAC,24 ~ 48VDC DIN Rail Screw Terminal 0.1 Sec ~ 120 Hrs SPDT (1 Form C) 5A @ 250VAC Mechanical Relay Screwdriver Slot Input Voltage,Trigger Signal
H3FA-B-DC24
Omron Automation and Safety
39
3 days
-
MOQ: 1  MPQ: 1
RELAY TIME DELAY 60MIN 3A 250V
H3FA 24VDC Through Hole PC Pin 0.6 Sec ~ 60 Min DPST-NO/NC (1 Form A and B) 3A @ 250VAC Mechanical Relay Screwdriver Slot Input Voltage,Trigger Signal
H3FA-B-DC12
Omron Automation and Safety
6
3 days
-
MOQ: 1  MPQ: 1
RELAY TIME DELAY 60MIN 3A 250V
H3FA 12VDC Through Hole PC Pin 0.6 Sec ~ 60 Min DPST-NO/NC (1 Form A and B) 3A @ 250VAC Mechanical Relay Screwdriver Slot Input Voltage,Trigger Signal
H3CA-8-AC100/110/120
Omron Automation and Safety
6
3 days
-
MOQ: 1  MPQ: 1
RELAY TIME DELAY 9990HR 3A 250V
H3CA 100 ~ 120VAC Socketable Plug In,8 Pin (Octal) 0.1 Sec ~ 9990 Hrs DPDT (2 Form C) 3A @ 250VAC Mechanical Relay Thumbwheel Switches Input Voltage
H3CA-8H AC100/110/120
Omron Automation and Safety
3
3 days
-
MOQ: 1  MPQ: 1
RELAY TIME DELAY 9990HR 3A 250V
H3CA 100 ~ 120VAC Socketable Plug In,8 Pin (Octal) 0.1 Sec ~ 9990 Hrs SPDT (1 Form C) 3A @ 250VAC Mechanical Relay Thumbwheel Switches Input Voltage
H3M-DC24-B
Omron Automation and Safety
2
3 days
-
MOQ: 1  MPQ: 1
RELAY TIME DELAY 10MIN 5A 250V
H3M 24VDC Socketable Plug In,8 Pin (Octal) 0.1 Sec ~ 10 Min DPDT (2 Form C) 5A @ 250VAC Mechanical Relay Hand Dial Input Voltage
H3FA-SB-DC12/24
Omron Automation and Safety
1
3 days
-
MOQ: 1  MPQ: 1
RELAY TIME DELAY 60MIN TH
H3FA 12 ~ 24VDC Through Hole PC Pin 0.6 Sec ~ 60 Min - - Solid State Relay Screwdriver Slot Input Voltage,Trigger Signal
H3FA-A-DC12
Omron Automation and Safety
5
3 days
-
MOQ: 1  MPQ: 1
RELAY TIME DELAY 10MIN 3A 250V
H3FA 12VDC Through Hole PC Pin 0.1 Sec ~ 10 Min DPST-NO/NC (1 Form A and B) 3A @ 250VAC Mechanical Relay Screwdriver Slot Input Voltage,Trigger Signal
H3JA-8C AC100-120 10S
Omron Automation and Safety
1
3 days
-
MOQ: 1  MPQ: 1
RELAY TIME DELAY 10SEC 5A 250V
H3JA 100 ~ 120VAC Socketable Plug In,8 Pin (Octal) 1 Sec ~ 10 Sec DPDT (2 Form C) 5A @ 250VAC Mechanical Relay Hand Dial Input Voltage
H3JA-8C AC100-120 60M
Omron Automation and Safety
1
3 days
-
MOQ: 1  MPQ: 1
RELAY TIME DELAY 60MIN 5A 250V
H3JA 100 ~ 120VAC Socketable Plug In,8 Pin (Octal) 6 Min ~ 60 Min DPDT (2 Form C) 5A @ 250VAC Mechanical Relay Hand Dial Input Voltage
H3CA-8-AC200/220/240
Omron Automation and Safety
Inquiry
-
-
MOQ: 1  MPQ: 1
RELAY TIME DELAY 9990HR 3A 250V
H3CA 200 ~ 240VAC Socketable Plug In,8 Pin (Octal) 0.1 Sec ~ 9990 Hrs DPDT (2 Form C) 3A @ 250VAC Mechanical Relay Thumbwheel Switches Input Voltage
H3JA-8C AC100-120 10M
Omron Automation and Safety
Inquiry
-
-
MOQ: 1  MPQ: 1
RELAY TIME DELAY 10MIN 5A 250V
H3JA 100 ~ 120VAC Socketable Plug In,8 Pin (Octal) 1 Min ~ 10 Min DPDT (2 Form C) 5A @ 250VAC Mechanical Relay Hand Dial Input Voltage
H3JA-8C AC100-120 30S
Omron Automation and Safety
Inquiry
-
-
MOQ: 1  MPQ: 1
RELAY TIME DELAY 30SEC 5A 250V
H3JA 100 ~ 120VAC Socketable Plug In,8 Pin (Octal) 3 Sec ~ 30 Sec DPDT (2 Form C) 5A @ 250VAC Mechanical Relay Hand Dial Input Voltage
H3JA-8C AC100-120 60S
Omron Automation and Safety
Inquiry
-
-
MOQ: 1  MPQ: 1
RELAY TIME DELAY 60SEC 5A 250V
H3JA 100 ~ 120VAC Socketable Plug In,8 Pin (Octal) 6 Sec ~ 60 Sec DPDT (2 Form C) 5A @ 250VAC Mechanical Relay Hand Dial Input Voltage
H3JA-8C AC100-120 1S
Omron Automation and Safety
Inquiry
-
-
MOQ: 1  MPQ: 1
RELAY TIME DELAY 1SEC 5A 250V
H3JA 100 ~ 120VAC Socketable Plug In,8 Pin (Octal) 0.1 Sec ~ 1 Sec DPDT (2 Form C) 5A @ 250VAC Mechanical Relay Hand Dial Input Voltage
H3JA-8C AC100-120 30M
Omron Automation and Safety
Inquiry
-
-
MOQ: 1  MPQ: 1
RELAY TIME DELAY 30MIN 5A 250V
H3JA 100 ~ 120VAC Socketable Plug In,8 Pin (Octal) 3 Min ~ 30 Min DPDT (2 Form C) 5A @ 250VAC Mechanical Relay Hand Dial Input Voltage
H3JA-8C AC100-120 3H
Omron Automation and Safety
Inquiry
-
-
MOQ: 1  MPQ: 1
RELAY TIME DELAY 3HR 5A 250V
H3JA 100 ~ 120VAC Socketable Plug In,8 Pin (Octal) 0.3 Hrs ~ 3 Hrs DPDT (2 Form C) 5A @ 250VAC Mechanical Relay Hand Dial Input Voltage